Unknown

Dataset Information

0

Strut Inversion During Valve-in-Valve Transcatheter Aortic Valve Replacement: An Unknown Complication?


ABSTRACT: A 74-year-old man presented with failure of a bioprosthetic aortic valve implanted 7 years earlier, with a mean gradient of 44 mm Hg across the aortic valve. During valve-in-valve transcatheter aortic valve replacement, we came across an unusual complication of strut inversion at the lower end of the valve. (Level of Difficulty: Advanced.).

SUBMITTER: Batta A 

PROVIDER: S-EPMC9044293 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Strut Inversion During Valve-in-Valve Transcatheter Aortic Valve Replacement: An Unknown Complication?

Batta Akash A   Satish Sai S   Rajan Ajay A   Sonawane Anmol A   Sihag Bhupendra Kumar BK   Barwad Parag P  

JACC. Case reports 20220420 8


A 74-year-old man presented with failure of a bioprosthetic aortic valve implanted 7 years earlier, with a mean gradient of 44 mm Hg across the aortic valve. During valve-in-valve transcatheter aortic valve replacement, we came across an unusual complication of strut inversion at the lower end of the valve. (<b>Level of Difficulty: Advanced.</b>). ...[more]