Unknown

Dataset Information

0

Green and facile synthesis of water-soluble carbon dots from ethanolic shallot extract for chromium ion sensing in milk, fruit juices, and wastewater samples.


ABSTRACT: Self-functionalized carbon dots (CDs) were prepared from ethanolic shallot extract to obtain a total phenolic precursor. The total phenolic extract was then heated at 180 °C for four hours in an autoclave. Only 1 mg L-1 of CDs had high fluorescence emission at 430 nm after excitation at 340 nm and manifested a high selectivity for Cr(vi) ions. The inter- and intra-day emission stability, pH, ionic strength, solvent effect, Stern-Volmer constant, incubation time, speciation of Cr(iii) and Cr(vi) ions, and ion selectivity of the as-prepared CDs were investigated in detail. The proposed method was validated in 20-100 μM linearity with y = 2.2346x as the set-zero intercept linear equation, 0.9981 as the correlation coefficient, 3.5 μM as the limit of detection (LOD), 11.7 μM as the limit of quantification (LOQ), and 2.78% and 5.29% as the intra-day and inter-day relative standard deviations (RSD), respectively. The recovery of drinking water, milk, soymilk, fruit juices (apple and coconut), tap water, and chromium-coated industrial waste water by the investigated Cr sensor was found to be 78.58-119.69%. Therefore, the proposed Cr(vi) sensor had superior advantages of sensitivity, selectivity, rapidity, and reproducibility.

SUBMITTER: Sakaew C 

PROVIDER: S-EPMC9054292 | biostudies-literature | 2020 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Green and facile synthesis of water-soluble carbon dots from ethanolic shallot extract for chromium ion sensing in milk, fruit juices, and wastewater samples.

Sakaew Chinawooth C   Sricharoen Phitchan P   Limchoowong Nunticha N   Nuengmatcha Prawit P   Kukusamude Chunyapuk C   Kongsri Supalak S   Chanthai Saksit S  

RSC advances 20200529 35


Self-functionalized carbon dots (CDs) were prepared from ethanolic shallot extract to obtain a total phenolic precursor. The total phenolic extract was then heated at 180 °C for four hours in an autoclave. Only 1 mg L<sup>-1</sup> of CDs had high fluorescence emission at 430 nm after excitation at 340 nm and manifested a high selectivity for Cr(vi) ions. The inter- and intra-day emission stability, pH, ionic strength, solvent effect, Stern-Volmer constant, incubation time, speciation of Cr(iii)  ...[more]

Similar Datasets

| S-EPMC8982230 | biostudies-literature
| S-EPMC9463271 | biostudies-literature
| S-EPMC4526649 | biostudies-literature
| S-EPMC10835761 | biostudies-literature
| S-EPMC6429179 | biostudies-literature
| S-EPMC8904681 | biostudies-literature
| S-EPMC10552091 | biostudies-literature
| S-EPMC11011985 | biostudies-literature
| S-EPMC6950291 | biostudies-literature
| S-EPMC10641228 | biostudies-literature