Unknown

Dataset Information

0

A Comprehensive Investigation of Contrast Sensitivity and Disk Halo in High Myopia Treated With SMILE and EVO Implantable Collamer Lens Implantation.


ABSTRACT:

Purpose

To investigate the clinical outcomes in small incision lenticule extraction (SMILE) and EVO implantable Collamer lens (ICL)-treated high myopia.

Methods

Thirty-three SMILE-treated and 32 EVO ICL-treated patients were included and followed up for 6 months. Subjective refraction, contrast sensitivity, and disk halo size were measured preoperatively and postoperatively. Patient-reported outcomes (PROs) were obtained at the final visit.

Results

Significant differences in efficacy and safety indices were observed between the SMILE and EVO ICL groups at 6 months postoperatively (P < 0.05). In the SMILE group, the mesopic contrast sensitivity at 2.2 cycles per degree (cpd) and photopic contrast sensitivity at 0.5, 3.4, and 7.1 cpd were significantly improved. In the EVO ICL group, the mesopic contrast sensitivity at 7.1 cpd and photopic contrast sensitivity at 0.5, 7.1, and 14.6 cpd were significantly improved. The halo radii after SMILE were significantly increased at 1 week, showed a decreasing trend at 1 month, returned to baseline at 3 months, and progressed stably at 6 months. However, it was unchanged in the EVO ICL group. Regarding subjective experience, haloes were the most common disturbance with mild and little bothersomeness after EVO ICL in contrast to starbursts after SMILE.

Conclusions

EVO ICL implantation yielded better visual outcomes, improved contrast sensitivity particularly at high spatial frequencies, had a stabler disk halo size, and increased incidence of haloes, with less influence than that of SMILE.

Translational relevance

The disk halo and PRO findings will be of benefit for consultations and evaluations in visual performance and disturbances.

SUBMITTER: Zhao W 

PROVIDER: S-EPMC9055559 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Comprehensive Investigation of Contrast Sensitivity and Disk Halo in High Myopia Treated With SMILE and EVO Implantable Collamer Lens Implantation.

Zhao Wuxiao W   Zhao Jing J   Han Tian T   Wang Jifang J   Zhang Zhe Z   Zhou Xingtao X  

Translational vision science & technology 20220401 4


<h4>Purpose</h4>To investigate the clinical outcomes in small incision lenticule extraction (SMILE) and EVO implantable Collamer lens (ICL)-treated high myopia.<h4>Methods</h4>Thirty-three SMILE-treated and 32 EVO ICL-treated patients were included and followed up for 6 months. Subjective refraction, contrast sensitivity, and disk halo size were measured preoperatively and postoperatively. Patient-reported outcomes (PROs) were obtained at the final visit.<h4>Results</h4>Significant differences i  ...[more]

Similar Datasets

| S-EPMC10392000 | biostudies-literature
| S-EPMC10150472 | biostudies-literature
| S-EPMC4130551 | biostudies-literature
| S-EPMC10435081 | biostudies-literature
| S-EPMC8979746 | biostudies-literature
| S-EPMC8105832 | biostudies-literature
| S-EPMC10267309 | biostudies-literature
| S-EPMC10161410 | biostudies-literature
| S-EPMC8843229 | biostudies-literature
| S-EPMC11557998 | biostudies-literature