Development of micropillar array electrodes for highly sensitive detection of biomarkers.
Ontology highlight
ABSTRACT: Micropillar array electrodes (μAEs) have been widely applied in electrochemical detection owing to their advantages of increased mass transport, lower detection limit, and potential to be miniaturized. This paper reports the fabrication, simulation, surface modification, and characterization of PDMS-based μAEs coated with gold films. The μAEs consist of 9 × 10 micropillars with a height of either 100 μm, 300 μm, or 500 μm in a 0.09 cm2 region. Numerical simulation was employed to study the influence of geometrical parameters on the current density. The μAEs were fabricated by soft lithography and characterized using both SEM and cyclic voltammetry. Experiments revealed that high pillars enabled enhanced voltammetric current density regardless of the scan rates. The platinum-pall
SUBMITTER: Chen C
PROVIDER: S-EPMC9057762 | biostudies-literature | 2020 Nov
REPOSITORIES: biostudies-literature
ACCESS DATA