Ontology highlight
ABSTRACT: Background
Short-stem implants in shoulder arthroplasty were recently developed and reported clinical outcomes are good. However, radiological analysis often reveals humeral stem misalignment in the frontal plane, along with high filling ratios that can lead to proximal bone remodeling under stress shielding. The aim of this cadaveric study was to test whether using compactors for standard-length (> 100 mm) stems to implant short (< 100 mm) stems reduces the risk of stem misalignment without compromising in terms of a higher filling ratio.Methods
In a cadaveric study, twenty short stems were implanted using instrumentation for standard-length stems. Alignment and filling ratios were evaluated on anteroposterior radiographs for both the compactors and the stems. The angular
SUBMITTER: Gunst S
PROVIDER: S-EPMC9070928 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature