Ontology highlight
ABSTRACT: Background
The size and versatility of anterolateral thigh (ALT) flap enables a bi-paddle flap to cover complex and extensive defects optimally. However, it is characterized by variations in the sources of blood vessels and in the number of perforators, which increases the chances of failure of harvesting a bi-paddle flap. We present our method to overcome such failure. This is the first study exploring the optimal salvaging algorithm to overcome harvesting failure with the bi-paddle ALT flap.Methods
From January 2014 to December 2020, in 9 patients to be treated with bi-paddle ALT flap for soft-tissue defects (range, 48-288 cm2), there was failure of flap harvest because of perforator variations. We redesigned and converted the flaps to other forms for harvest i
SUBMITTER: Yang X
PROVIDER: S-EPMC9096413 | biostudies-literature | 2022 Apr