Unknown

Dataset Information

0

Tricuspid Structural Valve Deterioration Treated with a Transcatheter Valve-in-Valve Implantation: A Single-Center Prospective Registry.


ABSTRACT: The valve-in-valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the tricuspid position. We report on the outcomes of patients treated by a transcatheter tricuspid valve-in-valve (TT-ViV) implantation for symptomatic SVD in the tricuspid position during the years 2010-2019 at our center. Three main outcomes were examined during the follow-up period: TT-ViV hemodynamic data per echocardiography, mortality and NYHA functional class. Our cohort consisted of 12 patients with a mean age 65.4 ± 11.9 years, 83.3% male. The mean time from initial valve intervention to TT-ViV was 17.4 ± 8.7 years. The indications for TT-ViV were varied (41.7% for predominant regurgitation, 33.3% for predominant stenosis and 25.0% with a mixed pathology). All patients were treated with a balloon-expandable device. The mean follow-up was 3.4 ± 1.3 years. Tricuspid regurgitation was ≥ moderate in 57.2% of patients prior to the procedure and this decreased to 0% following the procedure. The mean transtricuspid valve gradients mildly decreased from the mean pre-procedural values of 9.0 mmHg to 7.0 mmHg at one month following the procedure (p = 0.36). Mortality at one year was 8.0% (95% CI 0-23). At the baseline, 4 patients (33.3%) were in NYHA functional class III/IV; this was reduced to 2 patients (18.2%) at the one year follow-up and both were in NYHA III. The TT-ViV procedure offered a safe, feasible and less invasive treatment option for patients with SVD in our detailed cohort.

SUBMITTER: Schamroth Pravda N 

PROVIDER: S-EPMC9104146 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Tricuspid Structural Valve Deterioration Treated with a Transcatheter Valve-in-Valve Implantation: A Single-Center Prospective Registry.

Schamroth Pravda Nili N   Vaknin Assa Hana H   Levi Amos A   Witberg Guy G   Shapira Yaron Y   Vaturi Mordechai M   Orvin Katia K   Talmor Barkan Yeela Y   Hamdan Ashraf A   Mishaev Raffael R   Sharoni Ram R   Perl Leor L   Sagie Alexander A   Kornowski Ran R   Codner Pablo P  

Journal of clinical medicine 20220509 9


The valve-in-valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the tricuspid position. We report on the outcomes of patients treated by a transcatheter tricuspid valve-in-valve (TT-ViV) implantation for symptomatic SVD in the tricuspid position during the years 2010-2019 at our center. Three main outcomes were examined during the follow-up period: TT-ViV hemodynamic data per echocardiography, mortality and NYHA functional  ...[more]

Similar Datasets

| S-EPMC9086553 | biostudies-literature
| S-EPMC8458695 | biostudies-literature
| S-EPMC10944779 | biostudies-literature
| S-EPMC8167470 | biostudies-literature
| S-EPMC11907267 | biostudies-literature
| S-EPMC9830461 | biostudies-literature
| S-EPMC10808522 | biostudies-literature
| S-EPMC10957156 | biostudies-literature
| S-EPMC8373758 | biostudies-literature
| S-EPMC9857153 | biostudies-literature