Paradoxical venous air embolism detected with point-of-care ultrasound: a case report.


ABSTRACT: Venous air embolism (VAE) is an uncommon event consistent in the entrainment of air from any communication between the environment and the venous vasculature that could occur during central venous catheter (CVC) manipulation, and might trigger circulatory shock within minutes depending on the amount of air embolized. We present a case of a critical care patient who presented sudden clinical hemodynamic deterioration after the removal of central venous catheter. Hemodynamic evaluation with point-of-care ultrasound (POCUS) showed bubbles in both right and left heart cavities wherewith air embolism facilitated by heart septal defect was suspected. Therefore, the patient was reintubated, supported with vasopressors and a new CVC was inserted to proceed with air aspiration. Shortly after, the patient's hemodynamic status improved in terms of vital signs stabilization. 6 h after the event with optimal perfusion markers and diminished sedation, the patient showed left hemiparesis therefore a cerebral magnetic resonance (MRI) was also performed showing hyperintensity in the right precentral gyrus, so ischemic stroke without hemorrhagic transformation diagnosis was made, because of paradoxical embolism. This case report demonstrates the value of POCUS application as a diagnostic tool in the hemodynamically unstable patient.

SUBMITTER: Ruiz Avila HA 

PROVIDER: S-EPMC9116074 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Paradoxical venous air embolism detected with point-of-care ultrasound: a case report.

Ruiz Avila Hector Andres HA   García-Araque Hans Fred HF   Acosta-Gutiérrez Estivalis E  

The ultrasound journal 20220518 1


Venous air embolism (VAE) is an uncommon event consistent in the entrainment of air from any communication between the environment and the venous vasculature that could occur during central venous catheter (CVC) manipulation, and might trigger circulatory shock within minutes depending on the amount of air embolized. We present a case of a critical care patient who presented sudden clinical hemodynamic deterioration after the removal of central venous catheter. Hemodynamic evaluation with point-  ...[more]

Similar Datasets

| S-EPMC9969267 | biostudies-literature
| S-EPMC10563042 | biostudies-literature
| S-EPMC5367751 | biostudies-literature
| S-EPMC10438940 | biostudies-literature
| S-EPMC5794681 | biostudies-literature
| S-EPMC8422334 | biostudies-literature
| S-EPMC7954258 | biostudies-literature
| S-EPMC2850880 | biostudies-literature
| S-EPMC7676809 | biostudies-literature
| S-EPMC10332747 | biostudies-literature