Unknown

Dataset Information

A Modified Method for Measuring Pressure Drop in Non-medical Face Masks with Automated Data Acquisition and Analysis.


ABSTRACT:

Background

Non-medical face masks, such as face coverings donned by the general population play an important role in reducing transmission of respiratory pathogens. Pressure drop or breathability of such masks is an important attribute especially with the advent of new standards such as ASTM F3502-21 that have specified pressure drop limits for general use of face coverings. Although several standards are available that discuss pressure drop measurement techniques, the methodologies reported are typically complex or are part of more sophisticated and expensive instruments. Thus, the applicability of such methods is often limited to medical device manufacturers.

Objective and methods

This manuscript adapts from the pressure drop measurements proposed in British Standard EN 14

SUBMITTER: Herman A 

PROVIDER: S-EPMC9126268 | biostudies-literature | 2021 Dec

REPOSITORIES: biostudies-literature