Continuous flow hygroscopicity-resolved relaxed eddy accumulation (Hy-Res REA) method of measuring size-resolved sodium chloride particle fluxes.
Ontology highlight
ABSTRACT: The accurate representation of aerosols in climate models requires direct ambient measurement of the size- and composition-dependent particle production fluxes. Here, we present the design, testing, and analysis of data collected through the first instrument capable of measuring hygroscopicity-based, size-resolved particle fluxes using a continuous-flow Hygroscopicity-Resolved Relaxed Eddy Accumulation (Hy-Res REA) technique. The Hy-Res REA system used in this study includes a 3D sonic anemometer, two fast-response solenoid valves, two condensation particle counters, a scanning mobility particle sizer, and a hygroscopicity tandem differential mobility analyzer. The different components of the instrument were tested inside the US Environmental Protection Agency's Aerosol Test Facility for s
SUBMITTER: Meskhidze N
PROVIDER: S-EPMC9127749 | biostudies-literature | 2018 Jan
REPOSITORIES: biostudies-literature
ACCESS DATA