Ontology highlight
ABSTRACT: Background
Large amounts of data are collected in neonatal intensive care units, which could be used for research. It is unclear whether these data, usually sampled at a lower frequency, are sufficient for retrospective studies. We investigated what to expect when using one-per-minute data for descriptive statistics.Methods
One-per-second inspiratory oxygen and saturation were processed to one-per-minute data and compared, on average, standard deviation, target range time, hypoxia, days of supplemental oxygen, and missing signal.Results
Outcomes calculated from data recordings (one-per-minute = 92, one-per-second = 92) showed very little to no difference. Sub analyses of recordings under 100 and 200 h showed no difference.Conclusion
In our study, descriptive
SUBMITTER: Salverda HH
PROVIDER: S-EPMC9133439 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature