Unknown

Dataset Information

0

The Effectiveness and Tolerability of a Very Low-Volume Bowel Preparation for Colonoscopy Compared to Low and High-Volume Polyethylene Glycol-Solutions in the Real-Life Setting.


ABSTRACT: Adequate bowel cleansing is essential for high-quality colonoscopy. Recently, a new very low-volume 1 litre (1L) polyethylene glycol (PEG) plus ascorbate solution (ASC) has been introduced. Our aims were to assess the effectiveness and tolerability of this product compared to low-volume 2L PEG-ASC and high-volume 4L PEG solutions, in a real-life setting. In six endoscopy units in Sweden, outpatients undergoing colonoscopy were either prescribed solutions according to local routines, or the very low-volume solution in split dose regimen. Bowel cleansing effectiveness and patient experience was assessed using the Boston Bowel preparation scale (BBPS) and a patient questionnaire. A total of 1098 patients (mean age 58 years, 52% women) were included. All subsegment and the total BBPS scores were significantly greater for 1L PEG-ASC in comparison to other solutions (p < 0.05 for 1L PEG-ASC and 4L PEG for transverse and left colon, otherwise p < 0.001). Nausea was more frequent with 1L PEG-ASC compared to 2L PEG-ASC (p < 0.001) and vomiting were more often reported compared to both other solutions (p < 0.01 and p < 0.05 for 2L PEG-ASC and 4L PEG, respectively). Smell, taste, and total experience was better for 1L PEG-ASC compared to 4L PEG (p < 0.001), and similar compared to the 2L PEG-ASC. In conclusion, 1L PEG-ASC leads to better bowel cleansing compared to 2L PEG-ASC or 4L PEG products, with similar or greater patient satisfaction.

SUBMITTER: Bednarska O 

PROVIDER: S-EPMC9140572 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Effectiveness and Tolerability of a Very Low-Volume Bowel Preparation for Colonoscopy Compared to Low and High-Volume Polyethylene Glycol-Solutions in the Real-Life Setting.

Bednarska Olga O   Nyhlin Nils N   Schmidt Peter Thelin PT   Johansson Gabriele Wurm GW   Toth Ervin E   Lindfors Perjohan P  

Diagnostics (Basel, Switzerland) 20220506 5


Adequate bowel cleansing is essential for high-quality colonoscopy. Recently, a new very low-volume 1 litre (1L) polyethylene glycol (PEG) plus ascorbate solution (ASC) has been introduced. Our aims were to assess the effectiveness and tolerability of this product compared to low-volume 2L PEG-ASC and high-volume 4L PEG solutions, in a real-life setting. In six endoscopy units in Sweden, outpatients undergoing colonoscopy were either prescribed solutions according to local routines, or the very  ...[more]

Similar Datasets

| S-EPMC9453094 | biostudies-literature
| S-EPMC6237338 | biostudies-literature
| S-EPMC6512395 | biostudies-literature
| S-EPMC4423298 | biostudies-literature
| S-EPMC4047058 | biostudies-literature
| 2652315 | ecrin-mdr-crc
| S-EPMC3571759 | biostudies-literature
| S-EPMC10502556 | biostudies-literature
| S-EPMC4599153 | biostudies-literature
| S-EPMC3391000 | biostudies-literature