The effects of positive end-expiratory pressure on cardiac function: a comparative echocardiography-conductance catheter study.


ABSTRACT:

Background

Echocardiographic parameters of diastolic function depend on cardiac loading conditions, which are altered by positive pressure ventilation. The direct effects of positive end-expiratory pressure (PEEP) on cardiac diastolic function are unknown.

Methods

Twenty-five patients without apparent diastolic dysfunction undergoing coronary angiography were ventilated noninvasively at PEEPs of 0, 5, and 10 cmH2O (in randomized order). Echocardiographic diastolic assessment and pressure-volume-loop analysis from conductance catheters were compared. The time constant for pressure decay (τ) was modeled with exponential decay. End-diastolic and end-systolic pressure volume relationships (EDPVRs and ESPVRs, respectively) from temporary caval occlusion were analyzed with generalized linear mixed-effects and linear mixed models. Transmural pressures were calculated using esophageal balloons.

Results

τ values for intracavitary cardiac pressure increased with the PEEP (n = 25; no PEEP, 44 ± 5 ms; 5 cmH2O PEEP, 46 ± 6 ms; 10 cmH2O PEEP, 45 ± 6 ms; p < 0.001). This increase disappeared when corrected for transmural pressure and diastole length. The transmural EDPVR was unaffected by PEEP. The ESPVR increased slightly with PEEP. Echocardiographic mitral inflow parameters and tissue Doppler values decreased with PEEP [peak E wave (n = 25): no PEEP, 0.76 ± 0.13 m/s; 5 cmH2O PEEP, 0.74 ± 0.14 m/s; 10 cmH2O PEEP, 0.68 ± 0.13 m/s; p = 0.016; peak A wave (n = 24): no PEEP, 0.74 ± 0.12 m/s; 5 cmH2O PEEP, 0.7 ± 0.11 m/s; 10 cmH2O PEEP, 0.67 ± 0.15 m/s; p = 0.014; E' septal (n = 24): no PEEP, 0.085 ± 0.016 m/s; 5 cmH2O PEEP, 0.08 ± 0.013 m/s; 10 cmH2O PEEP, 0.075 ± 0.012 m/s; p = 0.002].

Conclusions

PEEP does not affect active diastolic relaxation or passive ventricular filling properties. Dynamic echocardiographic filling parameters may reflect changing loading conditions rather than intrinsic diastolic function. PEEP may have slight positive inotropic effects.

Clinical trial registration

https://clinicaltrials.gov/ct2/show/NCT02267291 , registered 17. October 2014.

SUBMITTER: Berger D 

PROVIDER: S-EPMC9151717 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

The effects of positive end-expiratory pressure on cardiac function: a comparative echocardiography-conductance catheter study.

Berger David D   Wigger Olivier O   de Marchi Stefano S   Grübler Martin R MR   Bloch Andreas A   Kurmann Reto R   Stalder Odile O   Bachmann Kaspar Felix KF   Bloechlinger Stefan S  

Clinical research in cardiology : official journal of the German Cardiac Society 20220406 6


<h4>Background</h4>Echocardiographic parameters of diastolic function depend on cardiac loading conditions, which are altered by positive pressure ventilation. The direct effects of positive end-expiratory pressure (PEEP) on cardiac diastolic function are unknown.<h4>Methods</h4>Twenty-five patients without apparent diastolic dysfunction undergoing coronary angiography were ventilated noninvasively at PEEPs of 0, 5, and 10 cmH<sub>2</sub>O (in randomized order). Echocardiographic diastolic asses  ...[more]

Similar Datasets

| S-EPMC6201576 | biostudies-literature
| S-EPMC10962429 | biostudies-literature
| S-EPMC2597499 | biostudies-literature
| S-EPMC10645805 | biostudies-literature
| S-EPMC4574463 | biostudies-literature
| S-EPMC9104897 | biostudies-literature
| S-EPMC3830652 | biostudies-literature
| S-EPMC4056428 | biostudies-literature
| S-EPMC10754699 | biostudies-literature
| S-EPMC6880369 | biostudies-literature