Effectiveness of Continuous Endotracheal Cuff Pressure Control for the Prevention of Ventilator-Associated Respiratory Infections: An Open-Label Randomized, Controlled Trial.


ABSTRACT:

Background

An endotracheal tube cuff pressure between 20 and 30 cmH2O is recommended to prevent ventilator-associated respiratory infection (VARI). We aimed to evaluate whether continuous cuff pressure control (CPC) was associated with reduced VARI incidence compared with intermittent CPC.

Methods

We conducted a multicenter open-label randomized controlled trial in intensive care unit (ICU) patients within 24 hours of intubation in Vietnam. Patients were randomly assigned 1:1 to receive either continuous CPC using an automated electronic device or intermittent CPC using a manually hand-held manometer. The primary endpoint was the occurrence of VARI, evaluated by an independent reviewer blinded to the CPC allocation.

Results

We randomized 600 patients; 597 received the