Unknown

Dataset Information

0

Under-5-Minute Immunoblot Assays by Vortex Fluidic Device Acceleration.


ABSTRACT: Unlocking the potential of personalized medicine in point-of-care settings requires a new generation of biomarker and proteomic assays. Ideally, assays could inexpensively perform hundreds of quantitative protein measurements in parallel at the bedsides of patients. This goal greatly exceeds current capabilities. Furthermore, biomarker assays are often challenging to translate from benchtop to clinic due to difficulties achieving and assessing the necessary selectivity, sensitivity, and reproducibility. To address these challenges, we developed an efficient (<5 min), robust (comparatively lower CVs), and inexpensive (decreasing reagent use and cost by >70 %) immunoassay method. Specifically, the immunoblot membrane is dotted with the sample and then developed in a vortex fluidic device (VFD) reactor. All assay steps-blocking, binding, and washing-leverage the unique thin-film microfluidics of the VFD. The approach can accelerate direct, indirect, and sandwich immunoblot assays. The applications demonstrated include assays relevant to both the laboratory and the clinic.

SUBMITTER: Sanders EC 

PROVIDER: S-EPMC9156566 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Under-5-Minute Immunoblot Assays by Vortex Fluidic Device Acceleration.

Sanders Emily C EC   Sen Sanjana R SR   Gelston Aidan A AA   Santos Alicia M AM   Luo Xuan X   Bhuvan Keertna K   Tang Derek Y DY   Raston Colin L CL   Weiss Gregory A GA  

Angewandte Chemie (International ed. in English) 20220412 23


Unlocking the potential of personalized medicine in point-of-care settings requires a new generation of biomarker and proteomic assays. Ideally, assays could inexpensively perform hundreds of quantitative protein measurements in parallel at the bedsides of patients. This goal greatly exceeds current capabilities. Furthermore, biomarker assays are often challenging to translate from benchtop to clinic due to difficulties achieving and assessing the necessary selectivity, sensitivity, and reproduc  ...[more]

Similar Datasets

| S-EPMC3722563 | biostudies-literature
| S-EPMC6014698 | biostudies-literature
| S-EPMC6542520 | biostudies-literature
| S-EPMC9052111 | biostudies-literature
| S-EPMC6645571 | biostudies-literature
| S-EPMC8840205 | biostudies-literature
| S-EPMC8943860 | biostudies-literature
| S-EPMC9066649 | biostudies-literature
| S-EPMC9943686 | biostudies-literature
| S-EPMC10096627 | biostudies-literature