Improving immunoassay detection accuracy of anti-SARS-CoV-2 antibodies through dual modality validation.


ABSTRACT: A novel test strategy is proposed with dual-modality detection techniques for COVID-19 antibody detection. The full-length S protein of SARS-CoV-2 was chemically immobilized on a glass surface to capture anti-SARS-CoV-2 IgG in patient serum and was detected through either Electrochemical Impedance Spectroscopy (EIS) or fluorescence imaging with labeled secondary antibodies. Gold nanoparticles conjugated with protein G were used as the probe and the bound GNP-G was detected through EIS measurements. Anti-human-IgG conjugated with the fluorescent tag Alexa Fluor 488 was used as the probe for fluorescence imaging. Clinical SARS-CoV-2 IgG positive serum and negative controls were used to validate both modalities. For fluorescence-based detection, a high sensitivity was noticed with a quantification range of 0.01-0.1 A.U.C. and a LOD of 0.004 A.U.C. This study demonstrates the possibility of utilizing different measurement techniques in conjunction for improved COVID-19 serology testing.

SUBMITTER: Ma Y 

PROVIDER: S-EPMC9167148 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Improving immunoassay detection accuracy of anti-SARS-CoV-2 antibodies through dual modality validation.

Ma Yuhao Y   To Daniel D   Zeng Jie J   Shoute Lian C T LCT   Wu Meng M   Babiuk Shawn S   Zhuo Ran R   Charlton Carmen C   Kanji Jamil N JN   Babiuk Lorne L   Chen Jie J  

Biosensors & bioelectronics: X 20220605


A novel test strategy is proposed with dual-modality detection techniques for COVID-19 antibody detection. The full-length S protein of SARS-CoV-2 was chemically immobilized on a glass surface to capture anti-SARS-CoV-2 IgG in patient serum and was detected through either Electrochemical Impedance Spectroscopy (EIS) or fluorescence imaging with labeled secondary antibodies. Gold nanoparticles conjugated with protein G were used as the probe and the bound GNP-G was detected through EIS measuremen  ...[more]

Similar Datasets

| S-EPMC8261139 | biostudies-literature
| S-SCDT-10_1038-S44318-024-00061-0 | biostudies-other
| S-EPMC7934617 | biostudies-literature
| S-BSST379 | biostudies-other
| S-EPMC7320699 | biostudies-literature
| S-EPMC9360774 | biostudies-literature
| S-EPMC8565458 | biostudies-literature
| S-EPMC9249772 | biostudies-literature
| S-EPMC9456190 | biostudies-literature
| S-EPMC10811470 | biostudies-literature