Diagnostic Accuracy and Optimal Cut-off of Controlled Attenuation Parameter for the Detection of Hepatic Steatosis in Indian Population.


ABSTRACT:

Background and aims

Ultrasound of the liver is not good to pick up mild steatosis. Controlled attenuation parameter (CAP) evaluated in transient elastography (FibroScan) is widely available in India. However, data regarding the diagnostic accuracy and optimal cut-off values of CAP for diagnosing hepatic steatosis are scarce in Indian population. MRI-PDFF is an accurate technique for quantifying hepatic steatosis. Thus, this study examined the diagnostic accuracy and optimal cut-off values of CAP for diagnosing steatosis with MRI-PDFF as reference standard.

Methods

A total of 137 adults underwent CAP and MRI-PDFF measurements prospectively. A subset of participants (n = 23) underwent liver biopsy as part of liver transplantation evaluation. The optimal cut-off values, area un

SUBMITTER: Kuchay MS 

PROVIDER: S-EPMC9168736 | biostudies-literature | 2022 May-Jun