Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today.


ABSTRACT:

Purpose

To compare the CFR-PEEK plates with conventional plates in fracture fixation with regards to clinical and radiological outcomes and complications.

Methods

A systematic literature search was conducted in four online databases independently by two reviewers using the Cochrane methodology for systematic reviews. The identified relevant studies were assessed against predetermined inclusion/exclusion criteria. Independent data extraction and assessment of risk of bias and study quality was carried out.

Results

Nine studies (patient n = 361) out of 6594 records were included for analysis: 2 RCTs (n = 63), 3 prospective cohort studies (n = 151), and 4 retrospective cohort studies (n = 147). Studies were grouped per anatomic area of fixation. Four studies (n = 200) examined fixation of proximal humerus fractures. Two studies (n = 74) examined fixation of distal radius fractures. Two studies (n = 53) assessed outcomes of fixation of distal femur fractures. One study (n = 87) assessed the outcomes of fixation of ankle fractures. All nine studies reported very high union rates (from 91% in distal femur to 100% in upper limb) for the CFR-PEEK plate groups and low complication rates. There was no significant difference in clinical outcomes, and rate of complications as compared to the conventional plate groups.

Conclusion

CFR-PEEK plates have high union rates in extremity fracture fixation similar to conventional plates with comparable good clinical outcomes and a very low and comparable rate of complications. Considering their advantages, CFR-PEEK plates seem to be valid alternative to conventional plating.

SUBMITTER: Chloros GD 

PROVIDER: S-EPMC9192460 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fracture fixation in extremity trauma with carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plates: evidence today.

Chloros George D GD   Prodromidis Apostolos D AD   Wilson Jo J   Giannoudis Peter V PV  

European journal of trauma and emergency surgery : official publication of the European Trauma Society 20210906 3


<h4>Purpose</h4>To compare the CFR-PEEK plates with conventional plates in fracture fixation with regards to clinical and radiological outcomes and complications.<h4>Methods</h4>A systematic literature search was conducted in four online databases independently by two reviewers using the Cochrane methodology for systematic reviews. The identified relevant studies were assessed against predetermined inclusion/exclusion criteria. Independent data extraction and assessment of risk of bias and study  ...[more]

Similar Datasets

| S-EPMC4198524 | biostudies-literature
| S-EPMC10189937 | biostudies-literature
| S-EPMC8866862 | biostudies-literature
| S-EPMC7301173 | biostudies-literature
| S-EPMC11380836 | biostudies-literature
| S-EPMC10982921 | biostudies-literature
| S-EPMC6247697 | biostudies-literature
| S-EPMC10650194 | biostudies-literature
| S-EPMC2529136 | biostudies-other
| S-EPMC4994767 | biostudies-literature