ABSTRACT: Objective
To compare glycemic control and treatment preference in children with type 1 diabetes (T1D) using sensor augmented pump (SAP) with predictive low glucose suspend (SmartGuard®) or pump with independent intermittent scanning continuous glucose monitoring (iscCGM, Freestyle libre ®).Methods
In this open label, cross-over study, children 6 to 14 years of age, treated with insulin pump for at least 6 months, were randomized to insulin pump and iscCGM (A) or SAP with SmartGuard® (B) for 5 weeks followed by 5 additional weeks. The difference in percentages of time in glucose target (TIT), (3.9 - 8.0 mmol/l), <3 mmol/l, > 8 and 10 mmol/l, were analyzed using linear mixed models during the final week of each arm and were measu