ABSTRACT: Objective
To evaluate the role of totally endoscopic robotic aortic valve replacement in cardiac surgery.Methods
Four cases of totally robotic aortic valve replacement (AVR) were conducted from December 2016 to July 2018. All operations were completed with the Da Vinci robot Si™ system (intuitive Surgical, Inc. Sunnyvale, C.A, USA). Patients were male, with a mean age of 42.8 ± 6.2 years (range 32-49).Results
AVR was completed with the Da Vinci Si™ system (intuitive Surgical, Inc. Sunnyvale, CA, USA). There was no mortality and no procedure-related morbidity. The mean cardiopulmonary bypass and mean cross-clamp time was 252 ± 13.6 min and 178.8 ± 17.1 min, respectively. The mean ICU time was 78.8 ± 27.1 h, and the mean hospital stay was 15 ± 3.5 d. During a mean fol