Unknown

Dataset Information

One-step single-tube accelerated quantitative nucleoprotein gene-specific reverse transcription loop-mediated isothermal gene amplification (RT-LAMP) assay for rapid, real-time & reliable clinical detection of Ebola virus.


ABSTRACT:

Background & objectives

Due to the absence of specific drugs or vaccines for Ebola virus disease, rapid, sensitive and reliable diagnostic methods are required to control the transmission chain of the disease and for better patient management. Isothermal amplification of nucleic acids has emerged as a promising alternative in which rapid and efficient amplification is achieved at a constant temperature without the thermal cycling required in PCR.

Methods

A one-step single-tube accelerated quantitative reverse trascription loop-mediated isothermal amplification (RT-LAMP) assay was developed by targeting the NP gene of 2014 Zaire Ebola virus (ZEBOV). The RT-LAMP assay was found to be specific for ZEBOV, without having any cross-reactivity with related haemorrhagic fever viral

SUBMITTER: Kumar JS 

PROVIDER: S-EPMC9205003 | biostudies-literature | 2021 Apr