Ultrasound Can Determine Joint Distraction During Hip Arthroscopy but Fluoroscopic-Guided Portal Placement Is Superior.


ABSTRACT:

Purpose

To compare joint distraction measured on ultrasound (US) with joint space width (JSW) measured on fluoroscopy in hip arthroscopy and to determine whether ultrasound guidance is as safe and effective as fluoroscopy, the current gold standard, for establishing arthroscopic portals.

Methods

Cadaveric whole-body specimens were positioned supine and subjected to 60 lbs. of unilateral axial traction using a distal femoral Steinman pin. Joint distraction was measured via JSW on fluoroscopic and ultrasound images. A single, fellowship-trained orthopaedic surgeon established anterolateral arthroscopy portals via ultrasound or fluoroscopic guidance in a randomized sequence. Total procedure time, number of times the spinal needle pierced the capsule, and iatrogenic chondral or