ABSTRACT: Filtering facepiece respirators have been widely used in the fields of occupational health and public hygiene, especially during the COVID-19 pandemic. In particular, disposable respirators have been in high demand, and the waste generated from these disposable products poses a problem for the environment. Here, we aimed to test a practical decontamination method to allow for the reuse of KN95 respirators. In this study, three types of KN95 respirators were heated at 80 °C and 90 °C for different durations (15 min, 30 min, 45 min, 1 h, 2 h, 3 h, 4 h, 6 h, 8 h, 10 h, and 24 h). The filtration efficiencies of the tested KN95 respirators before and after heating were measured, and the changes in microstructure were imaged with a scanning electron microscope (SEM). In addition, a neural networ