Unknown

Dataset Information

0

Conversion of Reactive Carbon Solutions into CO at Low Voltage and High Carbon Efficiency.


ABSTRACT: Electrolyzers are now capable of reducing carbon dioxide (CO2) into products at high reaction rates but are often characterized by low energy efficiencies and low CO2 utilization efficiencies. We report here an electrolyzer that reduces 3.0 M KHCO3(aq) into CO(g) at a high rate (partial current density for CO of 220 mA cm-2) and a CO2 utilization efficiency of 40%, at a voltage of merely 2.3 V. These results were made possible by using: (i) a reactive carbon solution enriched in KHCO3 as the feedstock instead of gaseous CO2; (ii) a cation exchange membrane instead of an anion exchange membrane, which is common to the field; and (iii) the hydrogen oxidation reaction (HOR) at the anode instead of the oxygen evolution reaction (OER). The voltage reported here is the lowest reported for any CO2 to CO electrolyzer that operates at high current densities (i.e., a partial current density for CO greater than 200 mA cm-2) with a CO2 utilization efficiency of greater than 20%. This study highlights how the choice of feedstock, membrane, and anode chemistries affects the rate and efficiency at which CO2 is converted into products.

SUBMITTER: Zhang Z 

PROVIDER: S-EPMC9228564 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Conversion of Reactive Carbon Solutions into CO at Low Voltage and High Carbon Efficiency.

Zhang Zishuai Z   Lees Eric W EW   Ren Shaoxuan S   Mowbray Benjamin A W BAW   Huang Aoxue A   Berlinguette Curtis P CP  

ACS central science 20220531 6


Electrolyzers are now capable of reducing carbon dioxide (CO<sub>2</sub>) into products at high reaction rates but are often characterized by low energy efficiencies and low CO<sub>2</sub> utilization efficiencies. We report here an electrolyzer that reduces 3.0 M KHCO<sub>3</sub>(aq) into CO(g) at a high rate (partial current density for CO of 220 mA cm<sup>-2</sup>) and a CO<sub>2</sub> utilization efficiency of 40%, at a voltage of merely 2.3 V. These results were made possible by using: (i)  ...[more]

Similar Datasets

| S-EPMC4579481 | biostudies-literature
| S-EPMC4726090 | biostudies-other
| S-EPMC9960053 | biostudies-literature
| S-EPMC6193734 | biostudies-other
| S-EPMC5663965 | biostudies-literature
| S-EPMC10318968 | biostudies-literature
| S-EPMC10235047 | biostudies-literature
| S-EPMC6534605 | biostudies-literature
| S-EPMC6525546 | biostudies-literature
| S-EPMC8333049 | biostudies-literature