Ontology highlight
ABSTRACT: Background
Re-operative mitral valve (MV) replacement is a high-risk procedure, therefore, transcatheter MV replacement (TMVR) is a promising therapeutic option.Aim
In this study, we aimed to evaluate the feasibility and safety of TMVR in patients with high surgical risk with degenerated mitral bioprostheses (TMViV), failed surgical rings (TMViR), and mitral annular calcification (TMViMAC).Methods
This is a retrospective cohort study that enrolled patients with high surgical risk who underwent TMVR from February 2017 to September 2020. The TMVR procedure was performed using Edwards SAPIEN-3 valves through the transseptal approach.Results
Sixty-four patients aged 62.7 ± 16.1 years with an STS score of 9.2 ± 3.7% underwent TMVR [35 (55%) TMViV, 16 (25%) TMViR,
SUBMITTER: Taha FA
PROVIDER: S-EPMC9242753 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature