HoloLens 1 vs. HoloLens 2: Improvements in the New Model for Orthopedic Oncological Interventions.


ABSTRACT: This work analyzed the use of Microsoft HoloLens 2 in orthopedic oncological surgeries and compares it to its predecessor (Microsoft HoloLens 1). Specifically, we developed two equivalent applications, one for each device, and evaluated the augmented reality (AR) projection accuracy in an experimental scenario using phantoms based on two patients. We achieved automatic registration between virtual and real worlds using patient-specific surgical guides on each phantom. They contained a small adaptor for a 3D-printed AR marker, the characteristic patterns of which were easily recognized using both Microsoft HoloLens devices. The newest model improved the AR projection accuracy by almost 25%, and both of them yielded an RMSE below 3 mm. After ascertaining the enhancement of the second model in this aspect, we went a step further with Microsoft HoloLens 2 and tested it during the surgical intervention of one of the patients. During this experience, we collected the surgeons' feedback in terms of comfortability, usability, and ergonomics. Our goal was to estimate whether the improved technical features of the newest model facilitate its implementation in actual surgical scenarios. All of the results point to Microsoft HoloLens 2 being better in all the aspects affecting surgical interventions and support its use in future experiences.

SUBMITTER: Pose-Diez-de-la-Lastra A 

PROVIDER: S-EPMC9269857 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

HoloLens 1 vs. HoloLens 2: Improvements in the New Model for Orthopedic Oncological Interventions.

Pose-Díez-de-la-Lastra Alicia A   Moreta-Martinez Rafael R   García-Sevilla Mónica M   García-Mato David D   Calvo-Haro José Antonio JA   Mediavilla-Santos Lydia L   Pérez-Mañanes Rubén R   von Haxthausen Felix F   Pascau Javier J  

Sensors (Basel, Switzerland) 20220629 13


This work analyzed the use of Microsoft HoloLens 2 in orthopedic oncological surgeries and compares it to its predecessor (Microsoft HoloLens 1). Specifically, we developed two equivalent applications, one for each device, and evaluated the augmented reality (AR) projection accuracy in an experimental scenario using phantoms based on two patients. We achieved automatic registration between virtual and real worlds using patient-specific surgical guides on each phantom. They contained a small adap  ...[more]

Similar Datasets

| S-EPMC6199587 | biostudies-literature
| S-EPMC11927182 | biostudies-literature
| S-EPMC7375136 | biostudies-literature
| S-EPMC6167047 | biostudies-literature
| S-EPMC10907945 | biostudies-literature
| S-EPMC11350045 | biostudies-literature
| S-EPMC6526954 | biostudies-literature
| S-EPMC6604581 | biostudies-literature
| S-EPMC5220506 | biostudies-literature
| S-EPMC2920450 | biostudies-literature