Kissing Balloon "Valvuloplasty" of Obstructed Mechanical Aortic Valve: When You Are Running Out of Options.


ABSTRACT: We report an unusual case where "stuck" bileaflet aortic prosthetic valve occluders were partly released by performing emergency balloon dilatation with 2 noncompliant balloons by a percutaneous femoral approach. (Level of Difficulty: Advanced.).

SUBMITTER: Smith D 

PROVIDER: S-EPMC9270587 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Kissing Balloon "Valvuloplasty" of Obstructed Mechanical Aortic Valve: When You Are Running Out of Options.

Smith David D   Khurana Ayush A   Youhana Aprim A   Ionescu Adrian A  

JACC. Case reports 20220706 13


We report an unusual case where "stuck" bileaflet aortic prosthetic valve occluders were partly released by performing emergency balloon dilatation with 2 noncompliant balloons by a percutaneous femoral approach. (<b>Level of Difficulty: Advanced.</b>). ...[more]