Pacing lead extraction in the management of tricuspid regurgitation: a case report.


ABSTRACT:

Background

Patients with a cardiac implantable electronic device (CIED)-induced tricuspid regurgitation (TR) have an increased mortality and morbidity. However, the impact of CIED-lead extraction and its indications are not well-defined.

Case summary

A 69-year-old woman presented with recurrent hospital admissions for right heart failure refractory to medical therapy, on the background of a single-chamber permanent pacemaker (Biotronik) implanted 6 years ago for tachycardia-bradycardia syndrome. Transoesophageal echocardiography identified severe TR which was predominantly CIED-induced from a lead impingement of the posterior tricuspid valve (TV) leaflet preventing adequate leaflet coaptation. This had progressed to cause a degree of secondary functional TR. The patient underwent pacing lead extraction followed by epicardial lead placement via minithoracotomy, with significant symptomatic and echographic improvement of TR.

Discussion

CIED-induced TR from a lead impingement of TV leaflets carries the highest risk of TR and its consequences. This case illustrates the significance of the relationship between CIED-leads and the TV, which impacts management strategy. We recommend a mechanistic approach and incorporating CIED-lead interaction with the TV apparatus as the underlying principle in developing future management guidelines for CIED-induced TR.

SUBMITTER: Khor L 

PROVIDER: S-EPMC9295692 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pacing lead extraction in the management of tricuspid regurgitation: a case report.

Khor Lynn L   Madan Kedar K   Lee Choon Huat CH   Ng Martin K C MKC  

European heart journal. Case reports 20220517 7


<h4>Background</h4>Patients with a cardiac implantable electronic device (CIED)-induced tricuspid regurgitation (TR) have an increased mortality and morbidity. However, the impact of CIED-lead extraction and its indications are not well-defined.<h4>Case summary</h4>A 69-year-old woman presented with recurrent hospital admissions for right heart failure refractory to medical therapy, on the background of a single-chamber permanent pacemaker (Biotronik) implanted 6 years ago for tachycardia-bradyc  ...[more]

Similar Datasets

| S-EPMC11694657 | biostudies-literature
| S-EPMC5418555 | biostudies-literature
| S-EPMC10658346 | biostudies-literature
| S-EPMC11282457 | biostudies-literature
| S-EPMC11600958 | biostudies-literature
| S-EPMC6439371 | biostudies-literature
| S-EPMC8441198 | biostudies-literature
| S-EPMC7858028 | biostudies-literature
| S-EPMC11381278 | biostudies-literature