Adaptive carbon ion radiotherapy for locally advanced non-small cell lung cancer: Organ-sparing potential and target coverage.


ABSTRACT:

Background

The dose distribution of carbon ion radiotherapy (CIRT) for locally advanced non-small cell lung cancer (LANSCLC) is highly sensitive to anatomical changes.

Purpose

To demonstrate the dosimetric benefits of adaptive CIRT for LANSCLC and compare the differences between patients with and without adaptive plans based on dosimetry and clinical effect factors.

Materials and methods

Of the 98 patients with LANSCLC receiving CIRT, 31 patients underwent replanning following re-evaluations that revealed changes that would have compromised the dose coverage of the target volume or violated dose constraints. Dosimetric parameters and clinical factors were compared between patients with and without adaptive plans. Multivariate analysis identified factors influencing th

SUBMITTER: Jia S 

PROVIDER: S-EPMC9314958 | biostudies-literature | 2022 Jun