Autopsy of Used Reverse Osmosis Membranes from the Largest Seawater Desalination Plant in Oman.
Ontology highlight
ABSTRACT: The Barka desalination plant, commissioned in 2018, is the largest desalination plant in Oman. It has a capacity of 281 MLD with a reverse osmosis (RO) first-pass recovery rate of 46%. As part of the standard operator practice, a membrane autopsy was conducted to determine the cause of reductions in membrane performance. This study investigated fouled membranes (model No. SW30HRLE-440) from two different locations in the membrane rack. Various analytical methods were used to conduct the membrane autopsy. Field-emission scanning electron microscopy/energy-dispersive X-ray (FESEM/EDS) analyses of membrane samples showed major components of inorganic foulants. Moreover, black and salt-like crystals deposited on the membrane surface revealed significant carbon (C) components and oxygen (O), wi