Application of one-third tubular steel plates and screws for fixation of medial column in pilon fractures.


ABSTRACT:

Background

The present study sought to explore the efficacy of one-third tubular steel plates and screws for the treatment of medial column of pilon fractures.

Methods

The present retrospective study comprised 40 subjects with Rüedi-Allgöwer type III pilon fractures that attended Northern Jiangsu People's Hospital from April 2016 to April 2019. Patients were assigned to 2 groups based on reconstruction and fixation components used on the medial column. The medial column of participants in the control group (n=20) was anchored using screws. The medial column for subjects in the treatment group (n=20) was reconstructed using a one-third tubular steel plate. The American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score at 1, 2, 3, 6, 12 and 24 months after operation, intraoperative blood loss, fracture healing time, preoperative detumescence duration, operation time, postoperative weightbearing duration, and postoperative Burwell-Charnley radiological score of the 2 groups were compared.

Results

The findings showed that intraoperative blood loss, preoperative detumescence time, and operation time for the treatment group were not statistically different relative to the control group (P>0.05). The fracture healing time and postoperative weightbearing time in the treatment group were 15.07±0.98 weeks and 6.91±0.61 weeks, respectively, while those in the control group were 15.84±0.59 weeks and 8.60±0.53 weeks, respectively (P<0.05). Patients in the treatment group showed markedly higher AOFAS scores relative to the AOFAS scores of subjects in the control group at month 1, 2, and 3 post-operation (P<0.05). AOFAS scores for the 2 groups were not significantly different at month 6, 12 and 24 post-operation. Subjects in the control group had a significantly lower Burwell-Charnley number radiology score relative to that of subjects in the treatment group (P<0.05).

Conclusions

The present findings show that the medial column of subjects with Rüedi-Allgöwer type III pilon fracture can be repaired using a one-third tubular steel plate. Compared with simple screw fixation, the use of a one-third tubular steel plate allows earlier postoperative weightbearing, decreases the rate of postoperative reduction loss, and leads to better clinical effects and prognosis.

SUBMITTER: Wang Z 

PROVIDER: S-EPMC9347046 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

Application of one-third tubular steel plates and screws for fixation of medial column in pilon fractures.

Wang Zhuo Z   Zhang Jian J   He Jin-Shan JS   Gao Hong-Wei HW   Chen Peng-Tao PT   Zhou Yue-Lai YL   Fang Yong-Chao YC   Lu Yao Y   Hu Le L  

Annals of translational medicine 20220501 9


<h4>Background</h4>The present study sought to explore the efficacy of one-third tubular steel plates and screws for the treatment of medial column of pilon fractures.<h4>Methods</h4>The present retrospective study comprised 40 subjects with Rüedi-Allgöwer type III pilon fractures that attended Northern Jiangsu People's Hospital from April 2016 to April 2019. Patients were assigned to 2 groups based on reconstruction and fixation components used on the medial column. The medial column of partici  ...[more]

Similar Datasets

| S-EPMC2505247 | biostudies-other
| S-EPMC8812225 | biostudies-literature
| S-EPMC8841627 | biostudies-literature
| S-EPMC10694941 | biostudies-literature
| S-EPMC10189937 | biostudies-literature
| S-EPMC8847917 | biostudies-literature
| S-EPMC7385877 | biostudies-literature
| S-EPMC3177482 | biostudies-literature
| S-EPMC10524202 | biostudies-literature
| S-EPMC8127419 | biostudies-literature