Characterizing force capability and stiffness of hip exosuits under different anchor points.


ABSTRACT: Exosuits have been broadly researched owing to their benefits from soft and deformable nature. However, compared to exoskeletons, the exosuits have disadvantages in that the deformation of suit and human tissue can cause dissipation, leading to low force transfer efficiency. In this study, we explore the force capability and human-suit stiffness depending on the anchor point positions of the exosuit, introducing a better understanding of exosuit design. We found the relationships between the anchor point position and the force capability, and the anchor point position and the human-suit stiffness by conducting human subject experiments. When the distance between the anchor point of the waist belt and the anchor point of the thigh brace increased, the force capability increased, whereas the