Comparison of mainstream end tidal carbon dioxide on Y-piece side versus patient side of heat and moisture exchanger filters in critically ill adult patients: a prospective observational study.


ABSTRACT: The purpose of the study was to investigate the accuracy of mainstream EtCO2 measurements on the Y-piece (filtered) side of the heat and moisture exchanger filter (HMEF) in adult critically ill patients, compared to that on the patient (unfiltered) side of HMEF. We conducted a prospective observational method comparison study between July 2019 and December 2019. Critically ill adult patients receiving mechanical ventilation with HMEF were included. We performed a noninferiority comparison of the accuracy of EtCO2 measurements on the two sides of HMEF. The accuracy was measured by the absolute difference between PaCO2 and EtCO2. We set the non-inferiority margin at + 1 mmHg in accuracy difference between the two sides of HMEF. We also assessed the agreement between PaCO2 and EtCO2 using Bland-Altman analysis. Among thirty-seven patients, the accuracy difference was - 0.14 mmHg (two-sided 90% CI - 0.58 to 0.29), and the upper limit of the CI did not exceed the predefined margin of + 1 mmHg, establishing non-inferiority of EtCO2 on the Y-piece side of HMEF (P for non-inferiority < 0.001). In the Bland-Altman analyses, 95% limits of agreement between PaCO2 and EtCO2 were similar on both sides of HMEF (Y-piece side, - 8.67 to  + 10.65 mmHg; patient side, - 8.93 to  + 10.67 mmHg). The accuracy of mainstream EtCO2 measurements on the Y-piece side of HMEF was noninferior to that on the patient side in critically ill adults. Mechanically ventilated adult patients could be accurately monitored with mainstream EtCO2 on the Y-piece side of the HMEF unless their tidal volume was extremely low.

SUBMITTER: Tamashiro S 

PROVIDER: S-EPMC9362078 | biostudies-literature | 2022 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of mainstream end tidal carbon dioxide on Y-piece side versus patient side of heat and moisture exchanger filters in critically ill adult patients: a prospective observational study.

Tamashiro Satoshi S   Nakayama Izumi I   Gibo Koichiro K   Izawa Junichi J  

Journal of clinical monitoring and computing 20220803 2


The purpose of the study was to investigate the accuracy of mainstream EtCO<sub>2</sub> measurements on the Y-piece (filtered) side of the heat and moisture exchanger filter (HMEF) in adult critically ill patients, compared to that on the patient (unfiltered) side of HMEF. We conducted a prospective observational method comparison study between July 2019 and December 2019. Critically ill adult patients receiving mechanical ventilation with HMEF were included. We performed a noninferiority compar  ...[more]

Similar Datasets

| S-EPMC9252871 | biostudies-literature
| S-EPMC10186330 | biostudies-literature
| S-EPMC8932153 | biostudies-literature
| S-EPMC11368163 | biostudies-literature
2015-10-24 | E-GEOD-74224 | biostudies-arrayexpress
| S-EPMC6471497 | biostudies-literature
2022-02-28 | GSE197259 | GEO
| S-EPMC3488539 | biostudies-other
| S-EPMC5448414 | biostudies-literature
| S-EPMC7870741 | biostudies-literature