ABSTRACT: Background
Capillary refill time (CRT) is a valuable tool for triage and to guide resuscitation. However, little is known about CRT kinetics after fluid infusion.Methods
We conducted a prospective observational study in a tertiary teaching hospital. First, we analyzed the intra-observer variability of CRT. Next, we monitored fingertip CRT in sepsis patients during volume expansion within the first 24 h of ICU admission. Fingertip CRT was measured every 2 min during 30 min following crystalloid infusion (500 mL over 15 min).Results
First, the accuracy of repetitive fingertip CRT measurements was evaluated on 40 critically ill patients. Reproducibility was excellent, with an intra-class correlation coefficient of 99.5% (CI 95% [99.3, 99.8]). A CRT variation larger tha