Unknown

Dataset Information

Mechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes.


ABSTRACT:

Objectives

Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The pressure-volume (PV) loop, from which the MP is calculated, is different for VCV compared with PCV. We aimed to compare the MP of VCV with zero pause time (VCV-0), VCV with 10% pause time (VCV-10), and PCV within patients in different patient categories based on severity of lung injury.

Design

In a proof-of-concept study, we enrolled 46 mechanically ventilated patients without spontaneous breathing efforts. Baseline measurements were done in pressure-controlled mode. Subsequently, measurements were done in VCV-0 and VCV-10. Tida

SUBMITTER: Rietveld PJ 

PROVIDER: S-EPMC9380695 | biostudies-literature | 2022 Aug

REPOSITORIES: biostudies-literature