Ontology highlight
ABSTRACT: Objectives
Bioprosthetic valve deterioration remains a major limitation following aortic valve replacement. Favorable results have been reported with an autologous pericardium aortic valve neocuspidization.Methods
Seventy patients (31 women and 39 men) (mean age, 62 ± 12 years) with aortic stenosis (n = 52 [74%]) or aortic regurgitation (n = 18 [26%]) underwent the aortic valve neocuspidization procedure. Thirty-four patients (49%) had a tricuspid valve, 35 (50%) had a bicuspid valve, and 1 (1%) had a monocuspid valve. European System for Cardiac Operative Risk Evaluation and Society of Thoracic Surgeons scores were, respectively, 2.2% ± 2% and 2.0% ± 1.8%. Four patients (6%) had active endocarditis and 2 (3%) had endocarditis sequelae. One patient (1%) had fibroelastoma. A
SUBMITTER: Khatchatourov G
PROVIDER: S-EPMC9390173 | biostudies-literature | 2021 Dec
REPOSITORIES: biostudies-literature