Electro dialysis reversal (EDR) performance for reject brine treatment of reverse osmosis desalination system.
Ontology highlight
ABSTRACT: In this study, the performance of bench-scale EDR was evaluated using the samples taken from the 1st and the 2nd stage RO from the Brackish Water Reverse Osmosis (BWRO) plant in Eshtehard, Iran. The measurements indicated that original TDS of the aquifer brackish water was equal to 3,229-3,664 mg/L, whereas TDS of the 1st stage RO brine was between 5,500 and 7,700 mg/L, that TDS of the 2nd stage RO brine was in the range of 9,500-10,600 mg/L. A batch bench-scale EDR system of 12 l/h was used with a direct electric current at three different scenarios. In the first, the brine was fed at 20°C (as a reference regulated point). In the second, temperature (14, 20, 26.5°C), and in the third, voltage were changed (6, 12, 18, 24 V) to investigate their influences on performance of the EDR process,
SUBMITTER: Ataei Far H
PROVIDER: S-EPMC9401187 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature
ACCESS DATA