Ontology highlight
ABSTRACT: Background
Post-systolic shortening index (PSI) is defined as myocardial shortening that occurs after aortic valve closure, and is an emerging measure of regional LV contractile dysfunction. PSI measurement variability amongst software vendor and its relationship with mechanical dyssynchrony and mechanical dispersion index (MDI) remains unknown. We evaluated PSI by speckle-tracking echocardiography from several vendors in patients with increased left ventricular wall thickness, and associations with MDI.Methods
This is a prospective cross-sectional study of 70 patients (36 hypertrophic cardiomyopathy [HCM], 18 cardiac amyloidosis and 16 healthy controls) undergoing clinically indicated echocardiography. PSI was measured using QLAB/aCMQ (Philips), QLAB/LV auto-trace (Philips
SUBMITTER: Saijo Y
PROVIDER: S-EPMC9409501 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature