Project description:Coronavirus disease 2019 (COVID-19) is caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A serological test is used to assess the efficacy of vaccination. It has been reported that anti-SARS-CoV-2 spike (S) and neutralizing antibody (Ab) levels are lower following vaccination in patients with rheumatic disease. Here, we investigated anti-SARS-CoV-2 S and neutralizing Abs in vaccinated rheumatoid arthritis (RA) patients in Japan. Anti-SARS-CoV-2 S and neutralizing Abs were quantified in 101 RA patients and 117 controls. Anti-SARS-CoV-2 S Ab levels were lower in RA patients than both earlier after vaccination in controls (mean RA 324.1 ± 591.8 SDM vs. control 1216.6 ± 854.4 [U/mL], p < 0.0001) and later after vaccination (324.1 ± 591.8 vs. 582.0 ± 415.6 [U/mL], p = 0.0002). The interval between vaccination of the RA patients and serum collection was longer than for controls early after vaccination (142.1 ± 31.6 vs. 98.3 ± 11.2 [days], p < 0.0001), but shorter than the later sample from the controls (142.1 ± 31.6 vs. 257.3 ± 11.2 [days], p < 0.0001). Importantly, anti-SARS-CoV-2 neutralizing Ab titers in RA patients were higher than in either early or later control samples (10.7 ± 4.9 vs. 8.6 ± 6.6 [%], p = 0.0072, and 10.7 ± 4.9 vs. 3.1 ± 3.7 [%], p < 0.0001, respectively). Anti-SARS-CoV-2 S Ab titers in vaccinated RA patients were lower than in controls, but they were influenced by other clinical manifestations. Anti-SARS-CoV-2 neutralizing Ab levels were independently increased in RA.
Project description:BackgroundSevere acute respiratory syndrome coronavirus 2 (SARS-CoV-2) vaccination is shown to prevent severe illness and death in hemodialysis (HD) patients, but the immune response to vaccines is reduced in this population. This study compared SARS-CoV-2 spike protein antibody titers between HD patients and healthy controls in Japan for up to 6 months following vaccination.MethodsA multi-institutional retrospective study at five clinics in Japan was conducted using 412 HD patients and 156 healthy controls who received two doses of the BNT162b2 (Pfizer-BioNTech) mRNA vaccine. Anti-SARS-CoV-2 spike protein S1 IgG antibody titers were measured at 1, 3, and 6 months after the second dose. The attenuation speed was calculated as slope (i.e., -β) using a linear mixed-effects model toward the log-transformed antibody titers.ResultsThe HD group had significantly lower month 1 antibody titers (Ab-titer-1) than the controls, and these remained lower through month 6 (95% CI: 2617.1 (1296.7, 5240.8) vs. 7285.4 (4403.9, 11,000.0) AU/mL at Ab-titer-1, and 353.4 (178.4, 656.3) vs. 812.0 (498.3, 1342.7) AU/mL at Ab-titer-6 (p < 0.001, respectively)). Lower log Ab-titer-1 levels in the HD group were significantly associated with a lower log Ab-titer-6 (0.90 [0.83, 0.97], p < 0.001). The -β values in the HD patients and healthy controls were -4.7 ± 1.1 and -4.7 ± 1.4 (year-1), respectively.ConclusionSARS-CoV-2 spike protein antibody titers were significantly lower in HD patients than in healthy controls at 1 (peak) and 6 months after the second vaccination. Low peak antibody titers contributed to low 6-month antibody titers.
Project description:Patients with underlying medical conditions are at high risk of developing serious symptoms of the coronavirus disease 2019 than healthy individuals; therefore, it is necessary to evaluate the immune response to vaccination among them to formulate precision and personalized vaccination strategies. However, inconsistent evidence exists regarding whether patients with underlying medical conditions have lower anti-SARS-CoV-2 spike IgG antibody titers. We performed a cross-sectional study enrolling 2762 healthcare workers who received second doses of BNT162b2 vaccination from three medical and research institutes between June and July, 2021. Medical conditions were surveyed by a questionnaire, and spike IgG antibody titers were measured with chemiluminescent enzyme immunoassay using serum collected on the median of 62 days after the second vaccination. Multilevel linear regression model was used to estimate geometric mean and ratio of mean (95% confidence interval, CI) for the presence and absence of medical conditions and treatments. Among all participants (median age, 40 years [interquartile range, 30-50]; male proportion, 29.4%), the prevalence of hypertension, diabetes, chronic lung disease, cardiovascular disease, and cancer was 7.5%, 2.3%, 3.8%, 1.8%, and 1.3%, respectively. Patients with treated hypertension had lower antibody titers than those without hypertension; the multivariable-adjusted ratio of mean (95% CI) was 0.86 (0.76-0.98). Patients with untreated and treated diabetes had lower antibody titers than those without diabetes; the multivariable-adjusted ratio of mean (95% CI) was 0.63 (0.42-0.95) and 0.77 (0.63-0.95), respectively. No substantial difference was observed between the presence or absence of chronic lung disease, cardiovascular disease, or cancer. Patients with untreated hypertension and patients with untreated and treated diabetes had lower spike IgG antibody titers than participants without those medical conditions, suggesting that continuous monitoring of antibody titers and further booster shots could be necessary to maintain adaptive immunity in patients with hypertension or diabetes.
Project description:Against the background of the current COVID-19 infection dynamics with its rapid spread of SARS-CoV-2 variants of concern (VOC), the immunity and the vaccine prevention of healthcare workers (HCWs) against SARS-CoV-2 continues to be of high importance. This observational cross-section study assesses factors influencing the level of anti-SARS-CoV-2-spike IgG after SARS-CoV-2 infection or vaccination. One thousand seven hundred and fifty HCWs were recruited meeting the following inclusion criteria: age ≥18 years, PCR-confirmed SARS-CoV-2 infection convalescence and/or at least one dose of COVID-19 vaccination. anti-SARS-CoV-2-spike IgG titers were determined by SERION ELISA agile SARS-CoV-2 IgG. Mean anti-SARS-CoV-2-spike IgG levels increased significantly by number of COVID-19 vaccinations (92.2 BAU/ml for single, 140.9 BAU/ml for twice and 1144.3 BAU/ml for threefold vaccination). Hybrid COVID-19 immunized respondents (after infection and vaccination) had significantly higher antibody titers compared with convalescent only HCWs. Anti-SARS-CoV-2-spike IgG titers declined significantly with time after the second vaccination. Smoking and high age were associated with lower titers. Both recovered and vaccinated HCWs presented a predominantly good humoral immune response. Smoking and higher age limited the humoral SARS-CoV-2 immunity, adding to the risk of severe infections within this already health impaired collective.
Project description:BackgroundTo develop an effective vaccine against a novel viral pathogen, it is important to understand the longitudinal antibody responses against its first infection. Here we performed a longitudinal study of antibody responses against SARS-CoV-2 in symptomatic patients.MethodsSequential blood samples were collected from 39 individuals at various timepoints between 0 and 154 days after onset. IgG or IgM titers to the receptor binding domain (RBD) of the S protein, the ectodomain of the S protein, and the N protein were determined by using an ELISA. Neutralizing antibody titers were measured by using a plaque reduction assay.FindingsThe IgG titers to the RBD of the S protein, the ectodomain of the S protein, and the N protein peaked at about 20 days after onset, gradually decreased thereafter, and were maintained for several months after onset. Extrapolation modeling analysis suggested that the IgG antibodies were maintained for this amount of time because the rate of reduction slowed after 30 days post-onset. IgM titers to the RBD decreased rapidly and disappeared in some individuals after 90 days post-onset. All patients, except one, possessed neutralizing antibodies against authentic SARS-CoV-2, which they retained at 90 days after onset. The highest antibody titers in patients with severe infections were higher than those in patients with mild or moderate infections, but the decrease in antibody titer in the severe infection cohort was more remarkable than that in the mild or moderate infection cohort.InterpretationAlthough the number of patients is limited, our results show that the antibody response against the first SARS-CoV-2 infection in symptomatic patients is typical of that observed in an acute viral infection.FundingThe Japan Agency for Medical Research and Development and the National Institutes of Allergy and Infectious Diseases.
Project description:Newly emerged pathogens such as SARS-CoV-2 highlight the urgent need for assays that detect levels of neutralizing antibodies that may be protective. We studied the relationship between anti-spike ectodomain (ECD) and anti-receptor binding domain (RBD) IgG titers, and SARS-CoV-2 virus neutralization (VN) titers generated by two different in vitro assays using convalescent plasma samples obtained from 68 COVID-19 patients, including 13 who donated plasma multiple times. Only 23% (16/68) of donors had been hospitalized. We also studied 16 samples from subjects found to have anti-spike protein IgG during surveillance screening of asymptomatic individuals. We report a strong positive correlation between both plasma anti-RBD and anti-ECD IgG titers, and in vitro VN titer. Anti-RBD plasma IgG correlated slightly better than anti-ECD IgG titer with VN titer. The probability of a VN titer ≥160 was 80% or greater with anti-RBD or anti-ECD titers of ≥1:1350. Thirty-seven percent (25/68) of convalescent plasma donors lacked VN titers ≥160, the FDA-recommended level for convalescent plasma used for COVID-19 treatment. Dyspnea, hospitalization, and disease severity were significantly associated with higher VN titer. Frequent donation of convalescent plasma did not significantly decrease either VN or IgG titers. Analysis of 2,814 asymptomatic adults found 27 individuals with anti-RBD or anti-ECD IgG titers of ≥1:1350, and evidence of VN ≥1:160. Taken together, we conclude that anti-RBD or anti-ECD IgG titers can serve as a surrogate for VN titers to identify suitable plasma donors. Plasma anti-RBD or anti-ECD titer of ≥1:1350 may provide critical information about protection against COVID-19 disease.
Project description:BackgroundA community COVID-19 outbreak caused by the B.1.1.7 SARS-CoV-2 variant occurred in Taiwan in May 2021. High-risk populations such as people living with HIV (PLWH) were recommended to receive two doses of COVID-19 vaccines. While SARS-CoV-2 vaccines have demonstrated promising results in general population, real-world information on the serological responses remains limited among PLWH.MethodsPLWH receiving the first dose of SARS-CoV-2 vaccine from 2020 to 2021 were enrolled. Determinations of anti-SARS-CoV-2 spike IgG titers were performed every one to three months, the third dose of the SARS-CoV-2 vaccine or confirmed SARS-CoV-2 infection. All serum samples were tested for anti-nucleocapsid antibody and those tested positive were excluded from analysis.ResultsA total of 1189 PLWH were enrolled: 829 (69.7%) receiving two doses of the AZD1222 vaccine, 232 (19.5%) of the mRNA-1273 vaccine, and 128 (10.8%) of the BNT162b2 vaccine. At all time-points, PLWH receiving two doses of mRNA vaccines had consistently higher antibody levels than those receiving the AZD1222 vaccine (p <0.001 for all time-point comparisons). Factors associated with failure to achieve an anti-spike IgG titer >141 BAU/mL within 12 weeks, included type 2 diabetes mellitus (DM) (adjusted odds ratio [aOR], 2.24; 95% CI, 1.25-4), a CD4 T cell count <200 cells/mm3 upon receipt of the first dose of vaccination (aOR, 3.43; 95% CI, 1.31-9) and two homologous AZD1222 vaccinations (aOR, 16.85; 95%CI, 10.13-28). For those receiving two doses of mRNA vaccines, factors associated with failure to achieve an anti-spike IgG titer >899 BAU/mL within 12 weeks were a CD4 T cell count <200 cells/mm3 on first-dose vaccination (aOR, 3.95; 95% CI, 1.08-14.42) and dual BNT162b2 vaccination (aOR, 4.21; 95% CI, 2.57-6.89).ConclusionsTwo doses of homologous mRNA vaccination achieved significantly higher serological responses than vaccination with AZD1222 among PLWH. Those with CD4 T cell counts <200 cells/mm3 and DM had consistently lower serological responses.
Project description:The presence of neutralizing antibodies against SARS-CoV-2 correlates with protection against infection and severe COVID-19 disease courses. Understanding the dynamics of antibody development against the SARS-CoV-2 virus is important for recommendations on vaccination strategies and on control of the COVID-19 pandemic. This study investigates the dynamics and extent of α-Spike-Ab development by different vaccines manufactured by Johnson & Johnson, AstraZeneca, Pfizer-BioNTech and Moderna. On day 1 after vaccination, we observed a temporal low-grade inflammatory response. α-Spike-Ab titers were reduced after six months of vaccination with mRNA vaccines and increased 14 days after booster vaccinations to a maximum that exceeded titers from mild and critical COVID-19 and Long-COVID patients. Within the group of critical COVID-19 patients, we observed a trend for lower α-Spike-Ab titers in the group of patients who survived COVID-19. This trend accompanied higher numbers of pro-B cells, fewer mature B cells and a higher frequency of T follicular helper cells. Finally, we present data demonstrating that past infection with mild COVID-19 does not lead to long-term increased Ab titers and that even the group of previously infected SARS-CoV-2 patients benefit from a vaccination six months after the infection.
Project description:The spread of the COVID-19 pandemic around the world has revealed that it is urgently important to develop rapid and inexpensive assays for antibodies in general and anti-SARS-CoV-2 IgG antibody (anti-SARS-CoV-2 spike glycoprotein S1 antibody) in particular. Herein we report a method to detect the anti-SARS-CoV-2 spike antibody level by using Janus emulsions or Janus particles as biosensors. Janus emulsions are composed of two immiscible hydrocarbon and fluorocarbon oils. The hydrocarbon/water interfaces are functionalized with a secondary antibody of IgG protein and SARS-CoV-2 spike receptor binding domain (RBD), to produce two different Janus emulsions. Mixtures of these Janus droplets enable the detection of the anti-SARS-CoV-2 spike IgG antibody in an agglutination assay caused by the antibody's binding to both the secondary antibody of IgG antibody and SARS-CoV-2 spike protein RBD. Both qualitative optical images and quantitative fluorescence spectra are able to detect the level of anti-SARS-CoV-2 spike antibody at concentrations as low as 0.2 μg/mL in 2 h. The detection results of clinical human serum samples using this agglutination assay confirm that this method is applicable to clinical samples with good sensitivity and specificity. The reported method is generalizable and can be used to detect other analytes by attaching different biomolecular recognition elements to the surface of the Janus droplets.