In Vivo Evaluation of PCL Vascular Grafts Implanted in Rat Abdominal Aorta.
Ontology highlight
ABSTRACT: Electrospun tissue-engineered grafts made of biodegradable materials have become a perspective search field in terms of vascular replacement, and more research is required to describe their in vivo transformation. This study aimed to give a detailed observation of hemodynamic and structural properties of electrospun, monolayered poly-ε-caprolactone (PCL) grafts in an in vivo experiment using a rat aorta replacement model at 10, 30, 60 and 90 implantation days. It was shown using ultrasound diagnostic and X-ray tomography that PCL grafts maintain patency throughout the entire follow-up period, without stenosis or thrombosis. Vascular compliance, assessed by the resistance index (RI), remains at the stable level from the 10th to the 90th day. A histological study using hematoxylin-eosin (H&E
SUBMITTER: Dokuchaeva AA
PROVIDER: S-EPMC9412484 | biostudies-literature | 2022 Aug
REPOSITORIES: biostudies-literature