Ontology highlight
ABSTRACT: Background
The prostate demonstrates inter- and intra- fractional changes and thus adaptive radiotherapy would be required to ensure optimal coverage. Daily adaptive radiotherapy for MRI-guided radiotherapy can be both time and resource intensive when structure delineation is completed manually. Contours can be auto-generated on the MR-Linac via a deformable image registration (DIR) based mapping process from the reference image. This study evaluates the performance of automatically generated target structure contours against manually delineated contours by radiation oncologists for prostate radiotherapy on the Elekta Unity MR-Linac.Methods
Plans were generated from prostate contours propagated by DIR and rigid image registration (RIR) for forty fractions from ten patients.
SUBMITTER: Sritharan K
PROVIDER: S-EPMC9424262 | biostudies-literature | 2022 Nov
REPOSITORIES: biostudies-literature