Identifying putative ventilation-perfusion distributions in COVID-19 pneumonia.
Ontology highlight
ABSTRACT: Busana et al. (doi.org/10.1152/japplphysiol.00871.2020) published 5 patients with COVID-19 in whom the fraction of non-aerated lung tissue had been quantified by computed tomography. They assumed that shunt flow fraction was proportional to the non-aerated lung fraction, and, by randomly generating 106 different bimodal distributions for the ventilation-perfusion ([Formula: see text]) ratios in the lung, specified as sets of paired values {[Formula: see text]}, sought to identify as solutions those that generated the observed arterial partial pressures of CO2 and O2 (PaCO2 and PaO2). Our study sought to develop a direct method of calculation to replace the approach of randomly generating different distributions, and so provide more accurate solutions that were within the measurement error
SUBMITTER: Xu H
PROVIDER: S-EPMC9426945 | biostudies-literature | 2022