Reliable estimation of SARS-CoV-2 anti-spike protein IgG titers from single dilution optical density values in serologic surveys.


ABSTRACT: Reliable and scalable seroepidemiology methods are needed to estimate SARS-CoV-2 incidence and monitor the dynamics of population-level immunity as the pandemic evolves. We aimed to evaluate the reliability of SARS-CoV-2 normalized ELISA optical density (nOD) at a single dilution compared to titers derived from serial dilutions. We conducted serial serosurveys within a community-based cohort in Salvador, Brazil. Anti-S IgG ELISA (Euroimmun AG) was performed with 5 serial 3-fold dilutions of paired sera from 54 participants. Changes in nOD reliably predicted increases and decreases in titers (98.1% agreement, κ = 95.8%). Fitting the relationship between nOD and interpolated titers to a log-log curve yields highly accurate predictions of titers (r2 = 0.995) and changes in titers (r2 = 0.975), using only 1 to 2 dilutions. This approach can significantly reduce the time, labor and resources needed for large-scale serosurveys to ascertain population-level changes in exposure and immunity.

SUBMITTER: Andrade Belitardo EMM 

PROVIDER: S-EPMC9428330 | biostudies-literature | 2022 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reliable estimation of SARS-CoV-2 anti-spike protein IgG titers from single dilution optical density values in serologic surveys.

Andrade Belitardo Emilia M M EMM   Nery Nivison N   Aguilar Ticona Juan P JP   Portilho Moyra Machado MM   Mello Iago O IO   Ribeiro Guilherme S GS   Reis Mitermayer G MG   Costa Federico F   Cummings Derek A T DAT   Ko Albert I AI   Fofana Mariam O MO  

Diagnostic microbiology and infectious disease 20220831 4


Reliable and scalable seroepidemiology methods are needed to estimate SARS-CoV-2 incidence and monitor the dynamics of population-level immunity as the pandemic evolves. We aimed to evaluate the reliability of SARS-CoV-2 normalized ELISA optical density (nOD) at a single dilution compared to titers derived from serial dilutions. We conducted serial serosurveys within a community-based cohort in Salvador, Brazil. Anti-S IgG ELISA (Euroimmun AG) was performed with 5 serial 3-fold dilutions of pair  ...[more]

Similar Datasets

| S-EPMC8502080 | biostudies-literature
| S-EPMC7852272 | biostudies-literature
| S-EPMC9877977 | biostudies-literature
| S-EPMC8594815 | biostudies-literature
| S-EPMC11206316 | biostudies-literature
| S-EPMC8890651 | biostudies-literature
| S-EPMC10079051 | biostudies-literature
| S-EPMC7932155 | biostudies-literature
| S-EPMC9520958 | biostudies-literature
| S-EPMC10461687 | biostudies-literature