PH-responsive cinnamaldehyde-TiO2 nanotube coating: fabrication and functions in a simulated diabetes condition.
Ontology highlight
ABSTRACT: Current evidence has suggested that diabetes increases the risk of implanting failure, and therefore, appropriate surface modification of dental implants in patients with diabetes is crucial. TiO2 nanotube (TNT) has an osteogenic nanotopography, and its osteogenic properties can be further improved by loading appropriate drugs. Cinnamaldehyde (CIN) has been proven to have osteogenic, anti-inflammatory, and anti-bacterial effects. We fabricated a pH-responsive cinnamaldehyde-TiO2 nanotube coating (TNT-CIN) and hypothesized that this coating will exert osteogenic, anti-inflammatory, and anti-bacterial functions in a simulated diabetes condition. TNT-CIN was constructed by anodic oxidation, hydroxylation, silylation, and Schiff base reaction to bind CIN, and its surface
SUBMITTER: Lee Y
PROVIDER: S-EPMC9444834 | biostudies-literature | 2022 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA