Mesh deformation: A mechanism underlying polypropylene prolapse mesh complications in vivo.
Ontology highlight
ABSTRACT: Polypropylene meshes used in pelvic organ prolapse (POP) repair are hampered by complications. Most POP meshes are highly unstable after tensioning ex vivo, as evidenced by marked deformations (pore collapse and wrinkling) that result in altered structural properties and material burden. By intentionally introducing collapsed pores and wrinkles into a mesh that normally has open pores and remains relatively flat after implantation, we reproduce mesh complications in vivo. To do this, meshes were implanted onto the vagina of rhesus macaques in nondeformed (flat) vs deformed (pore collapse +/- wrinkles) configurations and placed on tension. Twelve weeks later, animals with deformed meshes had two complications, (1) mesh exposure through the vaginal epithelium, and (2) myofibroblast prolifera
SUBMITTER: Knight KM
PROVIDER: S-EPMC9453339 | biostudies-literature | 2022 Aug
REPOSITORIES: biostudies-literature