Fixed-Bearing Trabecular Metal Total Ankle Arthroplasty Using the Transfibular Approach for End-Stage Ankle Osteoarthritis: An International Non-Designer Multicenter Prospective Cohort Study.


ABSTRACT: This multicenter prospective cohort study assessed the safety and performance of the Trabecular Metal Total Ankle System (TM Ankle; Zimmer) for primary total ankle arthroplasty (TAA).

Methods

One hundred and twenty-one consecutive patients qualifying for primary TAA were enrolled in the study. All patients received the TM Ankle implant. Clinical outcome examinations and radiographic evaluations were conducted at 6 weeks, 6 months, 1 year, 2 years, and 3 years. Patient-reported outcome measures (PROMs) were evaluated with use of the EuroQol-5 Dimensions questionnaire (EQ-5D), Ankle Osteoarthritis Scale (AOS), American Orthopaedic Foot & Ankle Society questionnaire (AOFAS), and patient satisfaction at each time point. Complications were classified according to the Canadian Orthopaedic Foot and Ankle Society (COFAS) system.

Results

The average AOFAS, EQ-5D, AOS pain, and AOS difficulty scores showed significant improvement at 6 weeks, 6 months, 1 year, 2 years, and 3 years as compared with the preoperative baseline (p < 0.001). The Kaplan-Meier survival estimate for revision when used in primary cases was 97.35% at 3 years. During the 3 years of follow-up, 9 patients showed abnormal radiographic findings. Two ankles had intraoperative complications, 38 had complications that were non-surgical or device-related, and 3 ankles underwent revision.

Conclusions

The results of the present study indicated that patient well-being significantly increased following TAA with use of the TM Ankle. Radiographic parameters also demonstrated a low incidence of abnormal findings.

Level of evidence

Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

SUBMITTER: D'Ambrosi R 

PROVIDER: S-EPMC9489156 | biostudies-literature | 2022 Jul-Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fixed-Bearing Trabecular Metal Total Ankle Arthroplasty Using the Transfibular Approach for End-Stage Ankle Osteoarthritis: An International Non-Designer Multicenter Prospective Cohort Study.

D'Ambrosi Riccardo R   Tiusanen Hannu Tapani HT   Ellington John Kent JK   Kraus Fabian F   Younger Alastair A   Usuelli Federico Giuseppe FG  

JB & JS open access 20220701 3


This multicenter prospective cohort study assessed the safety and performance of the Trabecular Metal Total Ankle System (TM Ankle; Zimmer) for primary total ankle arthroplasty (TAA).<h4>Methods</h4>One hundred and twenty-one consecutive patients qualifying for primary TAA were enrolled in the study. All patients received the TM Ankle implant. Clinical outcome examinations and radiographic evaluations were conducted at 6 weeks, 6 months, 1 year, 2 years, and 3 years. Patient-reported outcome mea  ...[more]

Similar Datasets

| S-EPMC10901057 | biostudies-literature
| S-EPMC5901517 | biostudies-literature
| S-EPMC8924090 | biostudies-literature
| S-EPMC2532087 | biostudies-other
| S-EPMC10695343 | biostudies-literature
| S-EPMC10612447 | biostudies-literature
| S-EPMC9134246 | biostudies-literature
| S-EPMC8185646 | biostudies-literature