Remotely Monitored Cardiac Implantable Electronic Device Data Predict All-Cause and Cardiovascular Unplanned Hospitalization.


ABSTRACT: Background Unplanned hospitalizations are common in patients with cardiovascular disease. The "Triage Heart Failure Risk Status" (Triage-HFRS) algorithm in patients with cardiac implantable electronic devices uses data from up to 9 device-derived physiological parameters to stratify patients as low/medium/high risk of 30-day heart failure (HF) hospitalization, but its use to predict all-cause hospitalization has not been explored. We examined the association between Triage-HFRS and risk of all-cause, cardiovascular, or HF hospitalization. Methods and Results A prospective observational study of 435 adults (including patients with and without HF) with a Medtronic Triage-HFRS-enabled cardiac implantable electronic device (cardiac resynchronization therapy device, implantable cardioverter-defibrillator, or pacemaker). Cox proportional hazards models explored association between Triage-HFRS and time to hospitalization; a frailty term at the patient level accounted for repeated measures. A total of 274 of 435 patients (63.0%) transmitted ≥1 high HFRS transmission before or during the study period. The remaining 161 patients never transmitted a high HFRS. A total of 153 (32.9%) patients had ≥1 unplanned hospitalization during the study period, totaling 356 nonelective hospitalizations. A high HFRS conferred a 37.3% sensitivity and an 86.2% specificity for 30-day all-cause hospitalization; and for HF hospitalizations, these numbers were 62.5% and 85.6%, respectively. Compared with a low Triage-HFRS, a high HFRS conferred a 4.2 relative risk of 30-day all-cause hospitalization (8.5% versus 2.0%), a 5.0 relative risk of 30-day cardiovascular hospitalization (3.6% versus 0.7%), and a 7.7 relative risk of 30-day HF hospitalization (2.0% versus 0.3%). Conclusions In patients with cardiac implantable electronic devices, remotely monitored Triage-HFRS data discriminated between patients at high and low risk of all-cause hospitalization (cardiovascular or noncardiovascular) in real time.

SUBMITTER: Sammut-Powell C 

PROVIDER: S-EPMC9496305 | biostudies-literature | 2022 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Remotely Monitored Cardiac Implantable Electronic Device Data Predict All-Cause and Cardiovascular Unplanned Hospitalization.

Sammut-Powell Camilla C   Taylor Joanne K JK   Motwani Manish M   Leonard Catherine M CM   Martin Glen P GP   Ahmed Fozia Zahir FZ  

Journal of the American Heart Association 20220809 16


Background Unplanned hospitalizations are common in patients with cardiovascular disease. The "Triage Heart Failure Risk Status" (Triage-HFRS) algorithm in patients with cardiac implantable electronic devices uses data from up to 9 device-derived physiological parameters to stratify patients as low/medium/high risk of 30-day heart failure (HF) hospitalization, but its use to predict all-cause hospitalization has not been explored. We examined the association between Triage-HFRS and risk of all-c  ...[more]

Similar Datasets

| S-EPMC7931840 | biostudies-literature
| S-EPMC10422690 | biostudies-literature
| S-EPMC9175259 | biostudies-literature
| S-EPMC9339254 | biostudies-literature
| S-EPMC9454026 | biostudies-literature
| S-EPMC10690544 | biostudies-literature
| S-EPMC10980926 | biostudies-literature
| S-EPMC4939310 | biostudies-other
| S-EPMC8129436 | biostudies-literature