Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse.
Ontology highlight
ABSTRACT: Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (MaPHorse1). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulting in 16 measures per examiner*head. Sagittal and transversal angle measures revealed low intraexaminer variability at scale-level independent mean SDs of α 0.58° and α 0.69°, respecti
SUBMITTER: Kau S
PROVIDER: S-EPMC9506125 | biostudies-literature | 2022 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA