Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse.


ABSTRACT: Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (MaPHorse1). Five examiners (two experienced, three inexperienced) measured six cadaver heads on 2 consecutive days in a blinded block-randomization design, resulting in 16 measures per examiner*head. Sagittal and transversal angle measures revealed low intraexaminer variability at scale-level independent mean SDs of α 0.58° and α 0.69°, respectively. Sagittal angle measures associate with low interexaminer variability, showing small mean angle differences (max. α 0.51° ± 0.35°), small scatter, and more consistent data reproducibility. Despite comparable mean interexaminer differences, the spread of transversal angle measures was relevantly higher using the proposed landmarks (average 2.2-fold higher interquartile range). The measurement performance of experienced and inexperienced examiners did not systematically differ. The time required for individual measurements was already comparable after 24/96 repetitions. This instrument may help deciphering sagittal angle normocclusal range and orthognathic dynamics and, with a proposed procedural amendment, transversal angle as well.

SUBMITTER: Kau S 

PROVIDER: S-EPMC9506125 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Intra- and Interexaminer Measurement Variability Analysis of an Orthodontic Gauge Device to Determine Incisor Occlusal Surface Angles in the Horse.

Kau Silvio S   Motter Katharina S KS   Moser Viktoria J VJ   Kunz João R JR   Pellachin Matteo M   Hartl Bettina B  

Veterinary sciences 20220907 9


Incisor malocclusions are common in horses. As yet, an evidence-based understanding of incisor occlusal surface angle dynamics and normocclusal range is missing. Orthodontic measuring devices could help unravel this information objectively but imply measurement validation. We evaluated intra- and interexaminer variability of repeated sagittal and transversal incisor occlusal surface angle measures using a commercial orthodontic gauge device (<i>MaPHorse1</i>). Five examiners (two experienced, th  ...[more]

Similar Datasets

| S-EPMC8374198 | biostudies-literature
| S-EPMC11602743 | biostudies-literature
| S-EPMC7160892 | biostudies-literature
| S-EPMC8770963 | biostudies-literature
| S-EPMC11479465 | biostudies-literature
| S-EPMC4634324 | biostudies-literature
| S-EPMC8384812 | biostudies-literature
| S-EPMC11431644 | biostudies-literature
| S-EPMC9348963 | biostudies-literature
| S-EPMC10492872 | biostudies-literature