Reliability and Usability Analysis of an Embedded System Capable of Evaluating Balance in Elderly Populations Based on a Modified Wii Balance Board.
Ontology highlight
ABSTRACT: This paper analyzes the reliability and usability of a portable electronic instrument that measures balance and balance impairment in older adults. The center of pressure (CoP) metrics are measured with a modified Wii Balance Board (mWBB) platform. In the intra- and inter-rater testing, 16 and 43 volunteers (mean 75.66 and standard deviation (SD) of 7.86 years and 72.61 (SD 7.86) years, respectively) collaborated. Five volunteer raters (5.1 (SD 3.69) years of experience) answered the System Usability Scale (SUS). The most reliable CoP index in the intra-examiner tests was the 95% power frequency in the medial-lateral displacement of the CoP with closed-eyes. It had excellent reliability with an intraclass correlation coefficient ICC = 0.948 (C.I. 0.862-0.982) and a Pearson's correlation co
SUBMITTER: Estevez-Pedraza AG
PROVIDER: S-EPMC9518410 | biostudies-literature | 2022 Sep
REPOSITORIES: biostudies-literature
ACCESS DATA