Unknown

Dataset Information

B2 puncture with forward-viewing EUS simplifies EUS-guided hepaticogastrostomy (with video).


ABSTRACT:

Background and objectives

EUS-guided hepaticogastrostomy (EUS-HGS) is in widespread use; however, there are few dedicated devices. The B2 route is technically easier than the B3 route for guidewire insertion, dilation, and stenting but if performed with conventional oblique-viewing (OV) EUS, B2 puncture can cause transesophageal puncture and severe adverse events. The aim of this study was to assess the efficacy of forward-viewing (FV) EUS, which we have developed to improve safety for B2 puncture in EUS-HGS (B2-EUS-HGS).

Patients and methods

This single-center retrospective study included 61 consecutive patients who underwent B2-EUS-HGS with FV between February 2020 and March 2021 at Aichi Cancer Center, Japan. The patients were prospectively enrolled, and clinical data wer

SUBMITTER: Okuno N 

PROVIDER: S-EPMC9526104 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature